bruce@zjlongwell.com    +86-18358274663
enLanguage
Cont

Have any Questions?

+86-18358274663

Oct 30, 2021

Operation and maintenance of industrial fans

1. Before starting the fan, it is necessary to check whether there is any foreign matter in the flow channel to prevent the impeller of the fan from being hit by foreign matter after starting, causing damage.


2. Before starting the fan, please read the start-up manual and the motor operation manual in detail, operate the start-up equipment as required, and start the fan in the order of first level and then second level, adjust the direction of rotation, and ensure the normal operation of the fan.


3. After the fan starts and reaches normal operation, observe in time: a. Whether the current of the motor exceeds the rated current; b. There is an abnormal sound in the fan flow path. If the problem is found, stop the machine and check in time. Can enter the state of normal movement.


4. When the fan is in use, there should be an operating record. The system will record the operation of the fan, including: a, the start and stop time of the fan, the reason for the stop; b, the ambient temperature, temperature and atmospheric pressure; c, the working voltage of the motor , Operating current, temperature of each bearing, temperature of motor stator. If any items exceeding the index are found to be shut down immediately for inspection; d. The wind pressure and air volume of the fan; e. The time, quantity and brand of the replacement of the motor bearing with the lithium-based molybdenum disulfide lubricant; f. Abnormal conditions found in the regular inspection; g. The detailed content and troubleshooting of the failure.


3


5. When you need to reverse the wind, first cut off the power supply and apply the hand brake. Slowly apply force when braking, and do not apply force at one time. Reverse rotation can be performed after the impeller stops rotating, otherwise electrical equipment may be burnt.


6. During the operation of the fan, the motor should be maintained according to the motor manufacturer's instructions, and an appropriate amount of molybdenum disulfide lithium-based grease lubricating oil should be added.


7. The fan is shut down regularly to check whether each component meets the requirements:

a. Check the front and rear bearings of the motor. If the problem is found, replace the bearing according to the model, and replace the molybdenum disulfide lithium-based lubricant. b. Check whether the blade is loose and whether the installation angle of the blade is the same as the original setting. Any problems should be dealt with in time. c. The adjustment method of the blade installation angle: According to the characteristic curve of the fan and the ventilation requirements of the mine, select the required installation angle. Open the hub cover, loosen the leaf handle nut, and press the selected installation angle on the scale on the drum surface of the hub. Align the front of the blade with the graduation line, tighten the leaf handle nut, lock the nut, cover the cover, and then the adjustment is complete.

Note: After adjusting the blades, be sure to check whether the installation angles of the blades are the same, otherwise, readjust it.


8. Always check the reliability of measuring instruments to prevent malfunctions of thermometers and ammeters from causing accidents.


9. Drivers and other personnel should conduct regular inspections. Once they find abnormal noise, vibration, temperature rise, etc., they should stop the machine immediately and start the machine after troubleshooting.